Jordan Lumber (6200015)
Last Update: 08/25/06 ----- 03469T18/FRO ----- EPA | DAQ | EPA-TTN
- T17 renewal issued with testing required for wood-fired boilers - 01/16/06. (W.Willets)
- Jordan submits application to correct heat input for drying kilns - 12/19/05.
- DAQ issues T16 for administrative change - 12/08/05. (W.Willets)
- DAQ issues T15 to expand operations; pmt includes boiler testing requirements - 11/07/05. (W.Willets)
- Jordan Lumber submits late Title V renewal request - 09/30/05. (S.Proctor)
- DAQ reviews air dispersion modeling for modification - 09/15/05. (T.Anderson)
- DAQ sends add info request and EI info letter - Aug 05. (S.Vozzo)
- Jordan Lumber submits application addendum. Facility is TIII major - 06/23/05. (S.Proctor)
- Jordan Lumber submits significant TV permit modification applic. - 04/11/05. (S.Proctor)
- DAQ conducts inspection of Jordan Lumber - 03/10/05. (R.Kennedy)
- DAQ conducts inspection of Jordan Lumber - 01/08/04. (R.Hayden)