Air Pollution Controls - Progress Energy Lee (9600017)

Last Update: 05/14/06 ----- 01812T28/FRO ----- EPA | DAQ | EPA-TTN
Air Pollution Controls

Source ID Source Description Control ID Control Description
Unit 1 Boiler one coal/No. 2 fuel oil/On-Specification Used No. 2 Fuel Oil-fired electric utility boiler (901 million Btu per hour nominally rated heat input) equipped with “WIR” NOX reduction technology --- “WIR” NOX reduction technology involves altered burner firing pattern and flue gas recirculation Unit 1 ESP one electrostatic precipitator (Research Cottrell cold-side model) equipped with a sulfur trioxide flue gas conditioning system
Unit 2 Boiler (PSD) one coal/No. 2 fuel oil/On-Specification Used No. 2 Fuel Oil-fired electric utility boiler (1062 million Btu per hour nominally rated heat input) equipped with a low-NOX burner system Unit 2 ESP one electrostatic precipitator (GE-Buell hot-side model)
Unit 3 Boiler one coal/No. 2 fuel oil/On-Specification Used No. 2 Fuel Oil/waste solvents-fired electric utility boiler (2567 million Btu per hour nominally rated heat input) equipped with a low-NOX burner system Unit 3 ESP one electrostatic precipitator (Research Cottrell cold-side model) equipped with a sulfur trioxide flue gas conditioning system


Current/Planned Controls per Clean Smokestacks Act

Facility Rating (MW) Existing ESP PostComb. NOx/Tech. Operation Year FGD/SO2 Tech. Operation Year
Prog.Energy Lee 410 Cold(1,3) Hot(2) ROFA(2) SCR(3) 2007, 2010 None ----

For the above table, the number in parenthesis identifies the boiler unit(s) equipped with the corresponding emission control technology. Projections supplied by Progress Energy.


Mercury (Hg) Emission Allocations

Facility Unit 2010-2017 (oz.) 2018-Later (oz.)
Progress Energy Lee 1 202 80
Progress Energy Lee 2 199 79
Progress Energy Lee 3 641 253

(Link to Hg Controls Performance)